Stainless Steel Centrifugal Pump Replacement Dimensions

Get Product Catalog & Support
Fill out the form to get full specs and case studies.
The CQB50-32-125 and CQB50-32-160 both have a DN50 suction connection and a DN32 discharge connection. The CQB manual shows different bolt circles and bolt-hole diameters at both ports. It also lists different overall lengths. If you order a stainless steel centrifugal pump replacement from the nominal port sizes alone, you may discover the mismatch when the new pump reaches the skid.
Before ordering, check three things together: the flange details, the position of the pump on the base, and the flow and head the process requires. The two CQB models make a useful comparison because the same nominal connections appear on pumps with different dimensions and hydraulic duties.
Table of Contents
ToggleMeasure the Existing Pump and Piping From a Fixed Reference
Start with clear photos of the pump and motor nameplates. Record the full model code, motor rating, electrical supply and operating speed where available. If the old pump has lost capacity, collect its original design duty as well as its current readings. A worn pump’s present output can understate what the process needs.
For the dimensional survey, choose a fixed reference such as the top of the skid and one identifiable edge or mounting hole. Use that same reference for the existing pump and the proposed replacement drawing. A flange face can sit at the right height and still be too far forward to meet the pipe.
| What to record | Why it matters |
|---|---|
| Suction centerline height and flange face position | Shows whether the inlet can meet the existing suction pipe |
| Discharge centerline position and flange face elevation | Shows whether the outlet can reach the existing discharge connection |
| Bolt-circle diameter, hole count and hole diameter at each flange | Determines whether the bolts will line up |
| Mating face, gasket arrangement and flange specification | Determines how the joint seals and which components fit |
| Base mounting pattern and motor-side clearance | Affects whether the replacement fits the skid and can be serviced in place |
Where the site procedure permits access to an isolated flange, confirm the bolt circle from the drawing or a direct measurement. On these four-hole patterns, measuring between the centers of two opposite holes gives the bolt-circle diameter. Record the hole diameter separately. A photo with a scale can help the supplier interpret the sketch, particularly where a pipe or valve obscures part of the connection.
Compare CQB50-32-125 and CQB50-32-160 Flange Dimensions
The following dimensions come from the CQB manual. The suction and discharge bolt circles are identified as D5 and D6 on the flange drawing. Overall length is marked L on the installation drawing.
| Dimension | CQB50-32-125 | CQB50-32-160 |
|---|---|---|
| Nominal suction × discharge | DN50 × DN32 | DN50 × DN32 |
| Suction flange bolt circle | 110 mm | 125 mm |
| Suction bolt holes | 4 × Ø14 mm | 4 × Ø18 mm |
| Discharge flange bolt circle | 90 mm | 100 mm |
| Discharge bolt holes | 4 × Ø14 mm | 4 × Ø18 mm |
| Overall length L | 633 mm | 653 mm |

For a skid built around the CQB50-32-125, the CQB50-32-160 has a suction bolt circle that is 15 mm larger and a discharge bolt circle that is 10 mm larger. The bolts will sit at different positions on both flanges. The manual also shows a 20 mm increase in overall length. Use the dimensioned drawing to locate where that difference falls on your skid and check it against the motor, guards and adjacent equipment.
The suffixes 125 and 160 identify the nominal impeller diameters in millimetres. Use the flange and installation tables to check the drilling and mounting layout. Request the drawing for the exact pump and motor assembly quoted, especially when the replacement must fit a skid with limited room.
Decide Whether the Existing Pipework Can Be Reused
Overlay the proposed pump drawing on a sketch of the existing skid. Start at the suction flange because any change there can affect both fit and suction conditions. Then check the discharge connection, base anchors and the space needed to withdraw the pump for service. Include nearby filter housings, valve handles, cable entries and guards in the clearance check.
If both pipe positions align but the flange drilling differs, ask the piping designer to review a suitable spool piece or adapter. Include the mating face, gasket material, pressure rating and chemical compatibility. Check the installed length of the adapter before ordering. Even a short added piece can move the pump far enough to affect the discharge connection or mounting holes.
If the revised suction route adds a reducer, elbow or extra pipe, include those losses in the suction review. Support the pipe independently and verify that the mating faces align before tightening. Using the flange bolts to pull a misaligned pipe into place can transfer load to the pump casing. HENNVI guide to chemical pump flange compatibility · KSB guidance on pump nozzle loads

Check Flow and Head Before Changing Models
Suppose the existing system was designed around 12.5 m³/h at 20 m. The CQB manual lists that point for the CQB50-32-125 at 2,900 rpm. At the same flow and speed, the CQB50-32-160 is listed at 32 m of head.
| Model at 2,900 rpm | Listed flow | Listed head |
|---|---|---|
| CQB50-32-125 | 12.5 m³/h | 20 m |
| CQB50-32-160 | 12.5 m³/h | 32 m |
The two rows show what each pump develops at the same reference flow. In the actual installation, the operating flow is where the selected pump curve meets the system curve. The higher-head model could move the operating point to a higher flow, depending on the piping, valve position and equipment resistance. Ask the supplier to plot the expected operating point and verify absorbed power, suction margin and the allowable operating range. Where filter loading or tank levels materially change resistance, review those conditions together. Hydraulic Institute guide to pump and system curves
For a replacement that changes from a mechanically sealed pump to a CQB magnetic drive pump, confirm the wetted materials, containment shell, static seals and bearings for the actual liquid. Include the concentration, temperature range, viscosity and specific gravity. The CQB manual states that the pumped liquid cools and lubricates internal components and prohibits dry running. Follow the approved filling, venting and startup procedure for the supplied assembly.
Record the Operating Condition After Installation
Once the pump runs steadily under the approved commissioning procedure, record flow, suction pressure, discharge pressure, motor current and speed or operating frequency. Add the liquid temperature, source tank level, valve positions and filter condition. This gives the maintenance team a baseline they can reproduce later.
If flow differs from the expected duty, compare readings taken at the same tank level, valve position and filter condition before deciding what changed. For example, a filter that was clean during commissioning may have a higher pressure drop in service. Recording pressure at the pump connections and across the filter helps identify where the additional resistance occurs.
Frequently Asked Questions
Can I replace a CQB50-32-125 with a CQB50-32-160?
Check the approved drawing and hydraulic duty first. The supplied manual shows differences in flange drilling, overall length and head at the same reference flow. If the proposed model meets the hydraulic duty, compare both mating flanges and the skid dimensions to determine what installation changes it would need.
What does CQB50-32-160 mean?
In the CQB manual’s model designation, 50 is the nominal suction diameter, 32 is the nominal discharge diameter and 160 is the nominal impeller diameter, all in millimetres. The flange drawing gives the separate bolt-circle and bolt-hole dimensions.
What should I send HENNVI for a replacement quote?
Send the existing pump and motor nameplates, required flow and total head, liquid properties and electrical supply. Include a skid sketch with flange face locations, suction centerline and discharge height, plus the bolt circles and hole sizes for both connections. If the pipework or base must stay in place, mark those constraints on the sketch. Request the outline and connection drawing for the proposed assembly before fabrication. Contact HENNVI
Technical data source · CQB Stainless Steel Magnetic Drive Centrifugal Pump Manual, printed pages 01 and 06–09. The tables above use the listed dimensions and performance data for the named models. Confirm the drawing and curve for the exact configuration supplied.
Need a Reliable Pump Solution for Corrosive Applications?
Hennvi Pump provides engineered chemical pump solutions including magnetic drive pumps, diaphragm pumps,centrifugal pumps, dosing pumps,vertical pumps and filtration systems for industrial applications. Share your working conditions and requirements with us. Our technical team will provide professional suggestions, datasheets and competitive pricing for your fluid‑handling solution.