Stainless Steel Centrifugal Pump Motor Sizing for Dense Liquids

Get Product Catalog & Support
Fill out the form to get full specs and case studies.
The CQB65-50-160 manual lists 25 m³/h at 32 m of head and 2,900 rpm, with 5.07 kW of shaft power at that tabulated point. For the same pump model, the manual lists two motor outputs by liquid density: 7.5 kW for the column marked ≤1.30 g/cm³ and 11 kW for the column marked ≤1.84 g/cm³.
If your process liquid reaches 1.45 g/cm³, start with the 11 kW catalogue entry when requesting a selection. Confirm the power requirement across the expected flow range, the magnetic coupling capacity and the operating limits of the exact pump build. This guide shows how to use those checks to size a stainless steel centrifugal pump motor for chemical transfer or circulation.
Table of Contents
ToggleStart With the Actual Flow, Head and Liquid Density
Write the required flow and total head as a pair. In a tank-to-tank transfer, review the lowest source level, the highest receiving level and any pressure difference between the vessels. For a circulation loop, include the pressure losses through the piping, valves, filter and other equipment at the target flow.
If the system specification gives pressure in bar, use the actual liquid density when converting it to head. A head of 32 m is equivalent to about 3.14 bar for liquid at 1,000 kg/m³ and 4.55 bar at 1,450 kg/m³. These values express the pressure equivalent of the same head. Actual gauge readings can also reflect differences in elevation and velocity between the measurement points.
Record liquid density at the operating temperature and concentration. Include the normal and highest expected density if batches vary. Also record viscosity, especially if the liquid thickens during a cold start or as concentration increases. Viscosity can affect flow, head and efficiency, so a significant change calls for a performance and power review. Iwaki stainless steel magnetic drive pump manual
Read the CQB Shaft Power and Motor Columns Separately
The CQB performance table gives shaft power at individual flow and head points. Its motor columns show the listed motor output for each liquid-density category. Read both parts of the table when comparing options.
| CQB65-50-160 at 2,900 rpm | Flow | Head | Listed shaft power | Listed NPSHr |
|---|---|---|---|---|
| Lower listed flow | 15 m³/h | 34 m | 4.34 kW | 3.5 m |
| Middle listed flow | 25 m³/h | 32 m | 5.07 kW | 3.5 m |
| Higher listed flow | 30 m³/h | 29.5 m | 5.48 kW | 4.0 m |
| Liquid density column in the CQB manual | Listed motor output |
|---|---|
| ≤1.30 g/cm³ | 7.5 kW |
| ≤1.84 g/cm³ | 11 kW |

In this table, shaft power rises from 5.07 to 5.48 kW as flow increases from 25 to 30 m³/h, even though head falls from 32 to 29.5 m. Review the highest credible shaft load across the expected operating range. A changed valve position, a lower-resistance pipe route or a clean filter can move the operating point away from the condition used for the initial selection. HENNVI guide to reading a CQB pump performance curve
Worked Example: How Density Changes Shaft Power
At the same flow, head and pump efficiency, the estimated shaft power increases with liquid density. Use the following relationship for a preliminary calculation.
Shaft power (kW) = ρ × g × Q × H ÷ (1,000 × η)
In this equation, ρ is density in kg/m³, g is gravitational acceleration at approximately 9.81 m/s², Q is flow in m³/s, H is head in metres, and η is pump efficiency expressed as a decimal.
Use the CQB65-50-160 reference duty of 25 m³/h at 32 m and assume 43% pump efficiency for both liquids. Converting 25 m³/h gives approximately 0.00694 m³/s.
| Assumed liquid density | Estimated shaft power at the same duty |
|---|---|
| 1,000 kg/m³ | 5.07 kW |
| 1,450 kg/m³ | 7.35 kW |

The example shows why the required shaft power can increase by about 45% even when the flow and head stay the same. For liquid at 1.45 g/cm³, the 11 kW entry comes from the manual’s density table. The 7.35 kW figure comes from a calculation at one assumed operating point. Use the manufacturer’s power curve and the proposed motor’s operating limits to evaluate the full duty range.
Verify the Magnetic Coupling, Casing Pressure and Suction Margin
The CQB is a magnetic drive centrifugal pump. The motor turns the outer magnet, which transmits torque through the containment shell to the inner rotor. When reviewing a higher-density service, ask the supplier to confirm that the proposed magnetic coupling can transmit the required torque across the expected flow and speed range. A larger motor leaves the coupling’s torque capacity unchanged unless the coupling configuration also changes.
Check the maximum expected casing pressure separately. Include inlet pressure and the highest differential pressure the pump may develop under the approved operating conditions. At the same head, a denser liquid produces a greater pressure rise. Verify the casing and connection ratings for the specific assembly and operating temperature.
Check suction conditions at the highest expected flow and the lowest running source level. The CQB manual shows 3.5 m NPSHr at 25 m³/h and 4.0 m at 30 m³/h for this model. Calculate available NPSH using the actual liquid vapor pressure and suction losses, then verify the required margin with the pump supplier. Where the installation uses a suction strainer, account for its resistance before its planned service point. Hydraulic Institute guidance on pump curves and NPSH
Frequently Asked Questions
Which motor does the CQB manual list for liquid at 1.45 g/cm³?
For the CQB65-50-160, a density of 1.45 g/cm³ exceeds the 1.30 g/cm³ threshold of the 7.5 kW column and falls within the ≤1.84 g/cm³ column, which lists 11 kW. Confirm the quoted motor, power curve, coupling and wetted materials for the actual service.
Will a larger motor increase the pump’s flow or head?
At the same speed and with the same impeller configuration, increasing the motor’s rated output leaves the hydraulic curve unchanged. If the process needs a different flow or head, check the pump and system curves together to determine which model, impeller or approved speed range can meet the duty.
What information should I send HENNVI for a CQB motor selection?
Send the required flow and total head, site voltage and frequency, chemical name and concentration, liquid temperature, density and viscosity ranges, and the suction layout. For a replacement pump, include the existing pump and motor nameplates and any measured flow, pressure and current. Note any operating conditions that could increase flow or expose the pump to a denser liquid. Contact HENNVI
Technical data source · CQB Stainless Steel Magnetic Drive Centrifugal Pump Manual, printed page 06, performance table. The shaft power example uses the stated flow, head, density and efficiency assumptions. Confirm the performance curve and motor configuration for the supplied pump.
Need a Reliable Pump Solution for Corrosive Applications?
Hennvi Pump provides engineered chemical pump solutions including magnetic drive pumps, diaphragm pumps,centrifugal pumps, dosing pumps,vertical pumps and filtration systems for industrial applications. Share your working conditions and requirements with us. Our technical team will provide professional suggestions, datasheets and competitive pricing for your fluid‑handling solution.