Magnetic Drive Pump Parts Explained with an HMX Teardown

Assembled HENNVI HMX magnetic drive pump with a black flanged casing and teal motor

Get Product Catalog & Support

Fill out the form to get full specs and case studies.

The main magnetic drive pump parts are the pump casing, impeller, inner magnet, outer drive magnet, containment shell, shaft and bearings, and static seal. If you’re looking for a replacement part for a HENNVI HMX pump, start with the complete model code and a photo of the part in question. A teardown photo helps show where the part fits, while the model code identifies the configuration you need to check.

The assembled HMX photos show two useful perspectives. From the pump end, you can see the flanged connections and the casing that encloses the liquid side. From the motor side, you can see the fan cover, terminal box, and mounting base. These views help you show a supplier where a question or problem originates before you discuss individual internal parts.

Inside a magnetic drive centrifugal pump, the motor turns an outer drive magnet. Its magnetic field drives the inner magnet and impeller across a stationary containment shell. The impeller moves liquid through the pump, and the casing directs that flow toward the discharge. The table below describes the usual functions of these components. Technical reference on magnetic drive pump construction

 

In a sealless magnetic drive pump, the motor shaft stays outside the liquid chamber, eliminating the rotating shaft seal at that boundary. The pump still relies on its stationary joints and the materials used there. Shaft and bearing materials should also be checked for the actual service conditions. Magnetic drive pump bearing materials

HMX pump-end and motor-end views with labels for the casing, flanged connections, terminal box, and motor fan cover
PartWhat it does
Pump casingEncloses the impeller chamber and forms the liquid path between the suction and discharge connections.
ImpellerAdds energy to the liquid as it rotates, enabling the pump to deliver flow against system head.
Inner magnetReceives torque from the outer magnet and turns with the impeller assembly.
Outer drive magnetRotates with the motor and transfers torque across the containment shell.
Containment shellForms a stationary barrier between the pumped liquid and the motor-side drive magnet.
Shaft and bearingsSupport and guide the rotating assembly. Their material configuration matters for chemical service.
Static sealSeals a joint between stationary components. A manufacturer’s drawing may identify it as an O-ring or gasket, depending on the design.

In a sealless magnetic drive pump, the motor shaft stays outside the liquid chamber, eliminating the rotating shaft seal at that boundary. The pump still relies on its stationary joints and the materials used there. Shaft and bearing materials should also be checked for the actual service conditions. Magnetic drive pump bearing materials

How to Read a Magnetic Drive Pump Exploded View

An exploded view shows how components sit relative to one another. Compare it with the complete pump first, then follow the parts from the flanged casing toward the motor side. This helps you describe whether you mean a casing component, an item inside the pump chamber, or part of the motor-side drive.

In the HMX teardown photo, the flanged pump casing is at one end of the layout. Several internal components are set apart from it, including cylindrical assemblies and a loose ring. If you’re referring to one of these parts in an inquiry, circle it on the photo or show its location relative to the casing. Use a model-specific parts list to confirm the official name, part number, and whether the item is supplied individually or as part of an assembly.

HMX pump teardown with the flanged casing on the left and separated components laid out beside it

What the HMX Model Code Tells You

The HENNVI HMX series is designed for chemical liquid circulation. The HMX section on page 4 of the HENNVI English product catalogue lists PP, CFRPP, PVDF, and CFRETFE pump material options. It also lists separate codes for the shaft, bearing, and elastomer, so the pump material code is only one part of identifying the complete configuration. HMX Series Magnetic Drive Pump specifications

 

Eight fields of the HMX catalog example HMX-F-44-0-C-C-V-5, detailed in the table below

The catalogue uses HMX-F-44-0-C-C-V-5 as an example:

Code positionMeaning
HMXHMX series
FCFRPP pump material
4440 × 40 mm port size
0½ hp motor power code
First CCeramic shaft
Second CCarbon bearing
VViton elastomer
550 Hz

The two C fields illustrate why the position of each character matters. One specifies the shaft and the other specifies the bearing. Port size alone is also insufficient for identification. The HMX-440 and HMX-441, for example, both have 40 × 40 mm ports in the catalogue, with listed motor outputs of 0.37 kW and 0.75 kW respectively. When checking fit, provide the complete model information from the installed pump.

What to Send When Requesting HMX Spare Parts

If you’re replacing a worn or damaged component, send enough information to identify both the pump and the part:

  1. A clear photo of the pump nameplate. Include the full HMX model code and serial number if shown. If the label is hard to read, check the original purchase documents.
  2. A photo of the part and its location. Include one view of the whole pump and a closer view of the component. Add any part number or marking you can read.
  3. The liquid and operating conditions. Provide the chemical name, concentration, operating temperature, and any cleaning or flushing liquids. Include required flow and head if you are considering a different pump configuration.
  4. The scope of the request. Specify whether you need help identifying one component, checking a replacement assembly, or reviewing a complete pump replacement.

If the process liquid has changed since the pump was installed, include that detail in your request. A part that fits physically still needs to be checked for compatibility with the liquid and the operating conditions.

Send your complete HMX model code, nameplate photo, and part photo so HENNVI can check the configuration and applicable replacement options. Contact HENNVI about HMX parts

Need a Reliable Pump Solution for Corrosive Applications?

Hennvi Pump provides engineered chemical pump solutions including magnetic drive pumps, diaphragm pumps,centrifugal pumps, dosing pumps,vertical pumps and filtration systems for industrial applications. Share your working conditions and requirements with us. Our technical team will provide professional suggestions, datasheets and competitive pricing for your fluid‑handling solution.