Chemical Dosing Pump Calibration for HENNVI EHN Pumps

Get Product Catalog & Support
Fill out the form to get full specs and case studies.
Chemical dosing pump calibration starts with measuring how much liquid the installed pump delivers over a known time. A pump setting helps you return to the same control position. A timed volume measurement tells you the delivery rate under the conditions of that test.
For an EHN installation, record the pump setting, liquid, suction conditions, and discharge pressure with the measured volume. Those details help you interpret the result if the pump delivers a different amount after a pressure change, service, or adjustment. HENNVI EHN Series Dosing Pump
Table of Contents
ToggleWhat to Record Before Measuring Dosing Pump Output
Start with the target feed rate, in the same unit you will use to report the test. For example, if the process requires 4.0 L/h of stock solution, compare the measured stock solution delivery with 4.0 L/h. If the process target is expressed as active chemical mass or concentration, establish the required solution feed rate before interpreting the pump measurement. HENNVI guide to chemical dosing pump selection and sizing
| Record | What to write down |
|---|---|
| Pump identity | Full EHN model code and the installed operating or control mode, if applicable. |
| Pump setting | The adjustment setting and any displayed or commanded stroke rate. |
| Liquid and supply | Liquid name, concentration, temperature, and the suction arrangement during the test. Note visible air if present. |
| Discharge conditions | Pressure at the defined measurement point, or a description of the approved test arrangement if pressure is unavailable. |
| Volume and time | Volume measured, elapsed time, and the method used to measure it. |
Use the approved calibration method for the installed equipment. An approved suction-side calibration column can provide a timed drawdown measurement where the installation is designed for it. Keep the test representative of the installed duty. Changing the discharge arrangement can change the backpressure and affect delivery. ProMinent metering pump technical guidance on calibration at backpressure

Calculate Actual Delivery in Liters per Hour
Use the volume delivered over the measurement interval. If you record volume in milliliters and time in minutes, the conversion is:
Delivery (L/h) = measured volume (mL) ÷ elapsed time (min) × 0.06
For example, suppose an approved test shows 120 mL in 2 minutes:
| Calculation | Result |
|---|---|
| 120 mL ÷ 2 min | 60 mL/min |
| 60 × 0.06 | 3.6 L/h |
| Difference from a target of 4.0 L/h | 0.4 L/h below target |
That is 10% below the illustrative target. These are example measurements. Use the tolerance defined for your process when deciding whether an adjustment is needed. Repeat the measurement at the same setting and conditions before interpreting a result that looks unusual.
Ask the supplier for a drawing that shows the mounting footprint, the assembly below the mounting plane, and the discharge connection. Include your field dimensions on the same reference system wherever possible.

What the EHN Specification Tells You
The EHN product information lists a stroke frequency of up to 360 strokes per minute and describes manual flow adjustment. The stroke rate is useful when recording how the pump was set, while the timed volume measurement establishes actual delivery for the particular installation. Use the applicable performance information for the exact model and its operating pressure when reviewing a result. HENNVI EHN technical specifications
Save the measured result alongside the setting. If you later change the setting, repeat the approved test and record the new result. Keeping both records makes it easier to compare delivery before and after an adjustment.
What to Check if the Result Changes Between Runs
- Similar readings that consistently miss the target. Check the target units, concentration basis, and whether the measurement was taken at the intended discharge pressure. Compare the result with the model’s performance information before adjusting the pump.
- Different readings at the same setting. Review whether the liquid supply, discharge pressure, or measurement conditions changed during the test. Record visible air, changes in liquid level, and any recent service to the dosing head or valves.
- A satisfactory test followed by poor delivery in service. Compare the test arrangement with the real injection point. Look for changes in line pressure, suction conditions, or control settings between the test and normal operation.
When several factors changed at once, record them before making another adjustment. A test record with the pressure, setting, and liquid conditions beside each volume reading is easier to interpret than a list of flow results on its own.
When Should You Recheck the Dosing Rate?
Recheck actual output after a pump-head or valve service, a significant pressure change, a change in stock solution, or a change in the required feed rate. Use a comparable measurement method so the old and new results can be interpreted together.
If you need help reviewing an EHN installation, send the full model code, target feed rate, measured volume and time, pump setting, liquid concentration and temperature, and discharge pressure. Mention whether the measurement was taken on the normal injection line or on an approved test setup. Contact HENNVI for an EHN dosing review
Need a Reliable Pump Solution for Corrosive Applications?
Hennvi Pump provides engineered chemical pump solutions including magnetic drive pumps, diaphragm pumps,centrifugal pumps, dosing pumps,vertical pumps and filtration systems for industrial applications. Share your working conditions and requirements with us. Our technical team will provide professional suggestions, datasheets and competitive pricing for your fluid‑handling solution.