High Head vs High Flow Magnetic Drive Pumps: HMX-452 and HMX-452H

Get Product Catalog & Support
Fill out the form to get full specs and case studies.
The HMX-452 and HMX-452H have the same listed motor output of 1.5 kW, yet their catalogue duty points differ. At 50 Hz, the HMX-452 is listed at 200 L/min at 19 m, while the HMX-452H is listed at 100 L/min at 29 m. Start with the flow your system needs and the total head it requires at that flow. Then check both values against the pump curve for the intended operating frequency.
Table of Contents
ToggleWhat Makes a Chemical Circuit Need More Flow or Head?
Flow tells you how much liquid moves through the process. A circulation loop may need a specified flow through a filter, heat exchanger or return manifold. For a transfer line, the target may come from the volume of liquid that must reach a receiving tank within a set time. If a bypass returns part of the pump discharge to the supply tank, distinguish the flow delivered to the process from the total flow through the pump.
Head tells you how much energy per unit weight the pump must add. In tank-to-tank transfer, a higher receiving liquid level can increase the required head. In a circulation loop, pressure losses across pipes, valves, filters and other equipment can account for much of the head. These losses change with flow and with the condition of the equipment.
Write the duty as one pair, such as 150 L/min at 18 m. Locate both values on the pump curve to see whether the model can deliver the required flow at that head. The maximum flow figure alone cannot answer that question. Hydraulic Institute guide to pump and system curves

HMX-452 and HMX-452H Catalogue Comparison
Both models belong to the HENNVI HMX series of sealless magnetic drive pumps for chemical circulation and transfer. The catalogue lists nominal inlet and outlet sizes of 50 × 40 mm, motor output of 1.5 kW, and a specific gravity limit of 1.2 for both entries. Confirm the connection drawing and liquid suitability for the ordered configuration. HENNVI HMX Series specifications
| Model | Motor output | Standard duty at 50 Hz | Standard duty at 60 Hz |
|---|---|---|---|
| HMX-452 | 1.5 kW | 200 L/min at 19 m | 200 L/min at 17.5 m |
| HMX-452H | 1.5 kW | 100 L/min at 29 m | 100 L/min at 28.5 m |
Start with the HMX-452 curve for duties near the higher-flow reference. Review the HMX-452H curve first when the duty calls for higher head at a lower flow. To compare the two models at the same flow, use their full performance curves. For example, the table does not show how much head either pump delivers at 150 L/min.

Check Both Ends of the Filter Cycle
Suppose a chemical circulation system requires 150 L/min. At that flow, it needs 18 m of head with a clean filter and 22 m near the planned filter changeout point. These are assumed system requirements for this example.
On the relevant 50 or 60 Hz pump curve, check the head available at 150 L/min. Then compare the full pump curve with the system curves for the clean and loaded filter conditions. In a fixed-speed system, added filter resistance typically moves the operating point toward lower flow. If the process must maintain 150 L/min throughout the filter cycle, verify how the pump and controls will deliver it. With a clean filter, check that flow, absorbed power and suction conditions stay within the allowable limits.
Use the filter supplier’s differential pressure at the target flow or measurements from the existing line. When measuring a running circuit, record flow and filter differential pressure together. A pressure drop measured at a lower flow can understate the head required to maintain the process target.

Confirm the Liquid and Installation Before Ordering
Send the chemical name, concentration, operating temperature range, specific gravity, viscosity and expected solids. Confirm the materials of the housing, impeller, shaft, bearings and static seals for the exact pump build. Ask for the absorbed power and suction requirements across the expected operating range, including the lowest source tank level. For a replacement pump, include the existing connection drawing and flange standard.

Frequently Asked Questions
Can I use the same selection at 50 Hz and 60 Hz?
Check the curve for the intended frequency. The HMX-452 catalogue pairs 200 L/min with 19 m at 50 Hz and 17.5 m at 60 Hz. Verify that the motor nameplate and supplied pump configuration match the site electrical supply.
Will a higher-head pump always increase circulation flow?
The new flow depends on where the pump curve intersects the system curve. Compare the head each candidate can deliver at the required process flow. Then check the expected operating points as the filter loads or valve positions change.
What should I send HENNVI for an HMX selection?
Send the required flow and total head together, the site frequency, and the normal and most demanding operating conditions. Include tank levels, pipe layout, filter differential pressure and liquid properties. For an existing pump, add the model code and any measured flow and pressure readings. Request an HMX selection review
Need a Reliable Pump Solution for Corrosive Applications?
Hennvi Pump provides engineered chemical pump solutions including magnetic drive pumps, diaphragm pumps,centrifugal pumps, dosing pumps,vertical pumps and filtration systems for industrial applications. Share your working conditions and requirements with us. Our technical team will provide professional suggestions, datasheets and competitive pricing for your fluid‑handling solution.