Selecting a Stainless Steel Magnetic Drive Pump for Solvent Transfer

HENNVI CQB stainless steel magnetic drive pump on the solvent transfer selection guide cover.

Get Product Catalog & Support

Fill out the form to get full specs and case studies.

A solvent transfer pump can meet the required flow and head while the supply tank is full, then lose stable flow as the tank empties. For a volatile liquid, the lower tank level reduces suction head. If the solvent also gets warmer, its vapor pressure can rise and reduce the available suction margin further.

When evaluating a stainless steel magnetic drive pump for solvent transfer, review the solvent’s composition, the complete list of wetted materials and the suction conditions at the most demanding point in the transfer cycle. A CQB performance table can help you shortlist a pump before those checks are complete. Hydraulic Institute guidance on vapor pressure and NPSH

A magnetic drive transmits torque through a containment shell and removes the need for a rotating shaft seal through that boundary. The process liquid still contacts components such as the casing, impeller, containment shell, internal bearings or sleeves, and static seals. Ask for a component-by-component material list for the exact pump being quoted. Hydraulic Institute overview of sealless pumps

The CQB manual lists 304, 304L, 316 and 316L among the material options for wetted components. It also includes a corrosion table specifically for 1Cr18Ni9Ti. Use that table only as a reference for the alloy named in its heading. For a solvent blend, provide the full composition, water content if relevant, normal and maximum temperatures, and any cleaning liquid the pump will see. Ask HENNVI to verify the actual casing, impeller, shell and seal materials against those conditions.

CQB pump beside a checklist of wetted materials to verify for solvent transfer.

Use CQB Data to Check the Solvent Duty

Suppose a transfer line requires 12.5 m³/h at 20 m. The CQB50-32-125 is a preliminary candidate based on the manual. The second row shows how the listed values change if the process needs a higher flow.

CQB50-32-125 at 2,900 rpmListed headListed NPSHrListed shaft power
12.5 m³/h20 m3.5 m1.62 kW
15 m³/h18.5 m4.0 m1.63 kW

If the line needs 15 m³/h at 20 m, the second row is already below the required head. For either duty, check available NPSH using the lowest operating tank level, the applicable vessel pressure, the solvent vapor pressure at the highest expected liquid temperature, and suction losses at the intended flow. Include the resistance of any suction strainer. Send those inputs with the inquiry so HENNVI can review the suction margin for the quoted configuration.

CQB pump beside an available NPSH checklist covering liquid level, vessel pressure, vapor pressure and suction losses.
Two CQB50-32-125 manual duty points showing flow, head and required NPSH at 2,900 rpm.

Review Priming, Low Flow and the Installation Area

The CQB manual explains that the pumped liquid cools and lubricates the internal bearings. Review how the pump will remain filled and how the system will be primed and vented before startup. For batch transfer, tell HENNVI what happens as the source vessel empties or the receiving valve closes. Ask for the allowable minimum operating flow and the appropriate low-level or loss-of-flow protection for the selected model.

If the solvent is flammable, have the site’s responsible team provide the hazardous-area classification and required documentation. Request the exact motor nameplate and applicable certificates for the quoted configuration, along with documentation for the other equipment required by the installation. A photograph is useful for identifying the assembly and connection arrangement. The quotation should identify the exact equipment and documentation supplied.

Frequently Asked Questions

Can the same CQB configuration handle two different solvents?

Review both liquids and any mixtures that may remain during changeover. Confirm wetted-material compatibility, operating temperature, suction margin and motor load for each service.

What should I send HENNVI for a solvent transfer pump review?

Send the solvent composition and concentration, temperature range, density, viscosity and vapor pressure if available. Include the required flow and head, lowest source liquid level, vessel pressure, suction piping layout and any site classification requirements. Ask HENNVI to confirm the complete CQB configuration, curve and wetted-material list for that duty.

CQB pump beside a four-item solvent transfer inquiry checklist.

Need a Reliable Pump Solution for Corrosive Applications?

Hennvi Pump provides engineered chemical pump solutions including magnetic drive pumps, diaphragm pumps,centrifugal pumps, dosing pumps,vertical pumps and filtration systems for industrial applications. Share your working conditions and requirements with us. Our technical team will provide professional suggestions, datasheets and competitive pricing for your fluid‑handling solution.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top